Backflow Assembly Installation in Ontario

Proper placement, height and clearance on every assembly we install.

A badly placed assembly can fail inspections or be impossible to test. We install yours above grade where required, at the right height, with clearance for testing, then test it and file the first report.

  • PriceFree quote
  • TimeUsually 1 day
  • TestIncluded
  • FilingIncluded

Want to get on the schedule? Call or book online.

What a good install looks like

  • Vacuum breakers above the highest downstream outlet
  • Freeze and theft protection where needed
  • Clearance for testers and repairs
  • RP assemblies above grade, never in a pit

Where an assembly should go

Where an assembly sits affects whether it can work and whether it passes inspection. RP assemblies must be installed above ground, with enough space under them for the relief valve to drain freely. Putting an RP in a pit or a box that floods is one of the most common mistakes we see.

Pressure vacuum breakers and spill-resistant vacuum breakers have to be higher than the highest sprinkler head or outlet they protect, usually by at least 12 inches. On hillside lots, that can mean placing the device near the top of the yard instead of by the meter.

Double checks have more flexibility and are sometimes placed in vaults, especially on fire lines, but they still need room to be tested and repaired.

Clearance and access

Since every assembly gets tested yearly, it has to be easy to reach. Testers need space for the gauge hoses at the test cocks, room to turn the shutoffs, and enough clearance to open the checks for repairs.

A device crammed against a wall, hidden in bushes or tucked into a tight ceiling space can make a quick test drag on, or make a repair require cutting pipe. We plan the install so that doesn't happen.

Access for testers matters too. Behind a gate is fine at a house. At a business, a spot testers can reach without an escort saves everyone time.

Protecting the device after it's in

Freezes aren't common here, but inland and higher areas can get a cold snap that cracks a brass body or bonnet in one night. Insulated covers or enclosures help where that's a risk.

Theft is often the bigger threat. Brass devices near streets and lots attract scrap thieves, and a stolen device means an open line and a rush repair. A locking cage on a concrete pad is the standard fix.

We'll suggest protection based on the location, and a cage or cover can be included in your installation quote.

Startup test and the first report

After installation and flushing, we test the new assembly using the same procedure as the yearly test. It confirms the device is installed right and working.

We file that first passing report with your district. That puts the device on record and sets its first annual due date. A copy goes to you.

After that, it needs a test every year. Add due date management if you'd like us to track the date and schedule it for you.

Raising or relocating an existing assembly

Some assemblies were installed in the wrong spot years ago: an RP in a pit, a PVB below the sprinklers or a device boxed in where no one can test it. Moving it is often the right fix.

Relocation involves new piping and fittings, and the device is retested afterward. If the old device is in good shape, we can often reuse it, which keeps the cost down.

Working with contractors

Construction projects have a lot of moving parts. We coordinate with general contractors, plumbers and landscapers to install the assembly at the right stage and test it once water is on.

Since final inspection often needs the startup report, we file it promptly.

Choosing materials and fittings

The assembly is only as good as what connects it. We use fittings rated for potable water and sized to match the device, with unions where they make future repairs easier. Larger assemblies get proper supports so the weight isn't hanging on the pipe.

Outdoor devices near sprinklers or soil get fittings that hold up to the weather. These details don't show on the test report, but they're the difference between an install that lasts and one that leaks in a few years.

After installation

The first test and report are included. From then on, plan on an annual test.

Questions

Can a PVB go next to the meter?

Only if the meter is higher than every sprinkler it protects. On sloped yards it often needs to go uphill.

How long does installation take?

Most installs for 2-inch and smaller assemblies take a day.

Can an RP go underground?

No. The relief valve has to drain, so RPs go above ground.

Do you add a cage or cover?

If theft or freezing is a risk, we recommend one and include it in the quote.

Can you move an existing assembly?

Yes. A moved assembly has to be retested afterward, and we include that.

Do you pour a pad for a cage?

Yes, when a cage is part of the job we include the pad it bolts to.

Why Ontario customers call us for backflow assembly installation

We're a local company that focuses on backflow prevention. Every test is run by a certified tester with a calibrated gauge, and every report is filed with your water district as part of the job, not as an add-on.

You'll know the price before any work starts. Testing is a flat $105 per device under 4 inches and $175 for 4 inches and up, and repairs, replacements and installs are quoted first. We answer the phone seven days a week from 6am to 12pm, same-week appointments are normal, and emergency calls are taken 24/7. When the job's done, you get a copy of the report by email so you always have proof on hand.

Backflow Assembly Installation in Ontario and nearby

Need backflow Assembly Installation outside Ontario? We also cover Upland, Montclair, Chino, Rancho Cucamonga and Pomona. Same-week visits are normal, and booking takes a couple of minutes.

Have a notice from your district?

Same-week appointments. We handle the paperwork.

Call NowSchedule