Picking the right preventer comes first. We look at how the water is used, check your district's requirements, size the device for your flow, and then install it so it can be tested every year.
- PriceFree quote
- TimeUsually 1 day
- TestIncluded
- FilingIncluded
Want to get on the schedule? Call or book online.
What decides the type
- Where it can be installed and tested
- Your district's requirements
- Pipe size and water demand
- What the water is used for
Matching the device to the risk
The type of backflow preventer you need depends on what could get into the water if it flowed backward. Districts group connections into hazard levels, and each level allows certain devices.
High-hazard uses, like medical and dental offices, car washes, chemical feeds and many commercial kitchens, generally need an RP assembly or an air gap. Lower-hazard connections, such as many fire sprinkler systems, can often use a double check. Irrigation systems that only face backsiphonage may use a pressure vacuum breaker or spill-resistant vacuum breaker.
Your water district has the final word. Before we quote, we confirm what the district requires for your connection so you don't pay for the wrong device.
Sizing the device
A backflow preventer has to be big enough to pass the water your property uses without dropping pressure too much. Every device causes some pressure loss, and an undersized one can leave upstairs fixtures weak or sprinklers sputtering.
We look at the pipe size, the peak water demand and the pressure available at the meter. For most homes in Ontario, that points to a 3/4-inch or 1-inch device. Commercial buildings and fire lines often need 2 inches and up.
Bigger isn't always better either. An oversized device costs more, takes more space and can be harder to keep passing. We size it for what you actually use.
District approval and permits
Requirements vary. Some districts want plans before a commercial install. Others just need the first test report afterward. Cities may ask for a plumbing permit, particularly on commercial and fire line work.
We'll let you know what applies to your job and build it into the schedule. Permits, when needed, are part of the plan from the start.
Once the device is in, we test it and file the first report, which adds it to the district's records and starts the yearly testing cycle.
Common reasons for a new preventer
New buildings are the most common reason. Commercial projects and homes with new irrigation usually need protection before the water service is signed off.
Adding equipment is another. Installing sprinklers, a pool, a boiler or a fire sprinkler line often brings a new requirement. Changing how a space is used, like store to restaurant, can too.
Other times a district review finds an unprotected connection. In every case, we confirm the right type, size it, install it and file the first test report.
Preventers for sprinkler systems
Irrigation is one of the top reasons for a new preventer. The right type depends on the district and the system: PVB, SVB, double check, or RP if fertilizer or chemicals will be injected.
We consider the slope of the property, valve locations and any planned chemical feed before recommending a device and spot.
Larger preventers
Commercial projects usually mean bigger devices plus plans, permits and coordination with other trades. Fire services typically use detector assemblies of 4 inches or more.
We coordinate with your contractor so the device goes in at the right stage and the startup test is complete ahead of final inspection.
Understanding your installation quote
Our quotes spell out the device type and size, labor, any piping or fitting work and optional extras like a cage or cover. The startup test and the first district report are included.
When a permit is required, the quote says so. Quotes are free, and you'll see the full price before anything is scheduled.
If you suspect an existing device is the wrong type, we can compare it to your district's rules and tell you whether it should be replaced or is fine as is.
Need help deciding?
See our RP vs. double check vs. PVB guide, or call and we'll look at it with you.
Questions
Will the district add the new device to its records?
Yes. Filing the first test report puts it on their list and sets the first annual due date.
Can I install a PVB instead of an RP to save money?
Only if your district allows it for your hazard. For high-hazard uses, an RP is usually required.
Do you pull permits?
When a permit is required, we let you know and include it in the plan.
Is installation priced up front?
Yes. You get a free quote after we look at the site.
Will my district need to approve it?
Many do. We check the requirements and handle the paperwork with you.
Can the wrong size cause problems?
Yes. Too small can drop pressure, and too big can cost more and be harder to keep passing.
How we handle backflow preventer installation in Ontario
Our approach is simple. Show up when we say we will, do the work right, and handle the paperwork so you don't have to. Every tester is certified, every gauge is kept in calibration, and filing with your water district is included.
Pricing is clear. Tests are a flat $105 for devices under 4 inches and $175 for 4 inches and larger, and anything beyond the test is quoted before we start. We're available seven days a week from 6am to 12pm, with emergency calls answered 24/7. Most Ontario appointments are within the same week, and you'll have a copy of your report by email when we're done.
Where we offer Backflow Preventer Installation
Our testers handle backflow Preventer Installation across Ontario and the surrounding area, from Upland, Montclair, Chino, Rancho Cucamonga and Pomona. Call for the next opening or schedule online.