Backflow Preventer Testing in Ontario

Testing for every common type of backflow preventer: RP, double check, PVB and SVB.

Each type of backflow preventer has its own test procedure and pass standard. An RP is checked for relief valve opening and both checks. A double check needs both checks to hold. A PVB or SVB is checked for the air inlet and the check. We run the right procedure for what you have.

  • Price$105 flat
  • TimeUnder an hour
  • SchedulingSame week
  • FilingIncluded

Pricing

Backflow sizeFlat fee per backflow
Under 4"$105
4" and larger$175

Includes the test and filing with your water district. No hidden fees.

Want to get on the schedule? Call or book online.

Devices we test

  • RP assemblies on commercial and high-hazard lines
  • PVBs and SVBs on irrigation
  • Double checks on fire lines and lower-hazard services
  • Detector assemblies on fire sprinkler services

How we test an RP or RPZ

RP assemblies, sometimes written RPZ, protect connections where the risk is highest: chemical feeds, medical equipment, boilers, car washes and similar uses. Inside are two check valves and a relief valve in the middle that opens to the air if pressure between the checks gets too close to the supply pressure.

When we test an RP, we measure when that relief valve opens and whether each check valve holds. Those readings go on the report your district reviews.

A dripping or spitting relief valve between tests usually means debris or wear on the first check. We note it on the visit and explain whether it needs attention now. Catching it early tends to be cheaper than waiting for a failed test or a valve that won't stop discharging.

Testing double check valve assemblies

Double check valve assemblies use two check valves back to back. There's no relief valve, so they're used where the hazard is lower, such as many fire sprinkler services and some landscape and building lines.

Testing one means checking each valve separately. The tester closes the shutoffs, connects the gauge to the test cocks and confirms both checks hold.

These devices are often in underground boxes or vaults. If yours tends to collect water, mud or critters, mention it when you schedule. We'll bring what we need to clear it out so the test can go ahead on the same trip.

Testing PVBs and SVBs

PVBs and SVBs are common on residential and commercial irrigation. They're the above-ground devices with a bonnet on top, usually near the sprinkler valves. Their job is to stop water from being siphoned back out of the sprinkler lines when pressure drops on the supply side.

The test checks two things: that the air inlet opens and that the check valve holds tight. It's quick, and these are often the easiest devices to reach.

Placement matters with these. They need to be above the highest downstream sprinkler or outlet to work as designed. If yours looks too low, we'll tell you, because a device can pass its readings and still be installed wrong.

Fire line and detector assemblies

Many commercial and multi-unit buildings have a double check detector assembly (DCDA) or a reduced pressure detector assembly (RPDA) on the fire sprinkler line. These have a small bypass with a meter that shows if water is being used on the fire line when it shouldn't be.

We test the main assembly and the bypass assembly, since both protect the water supply. Fire line devices are often 4 inches or larger, which falls in the $175 per device price tier.

Fire systems usually involve more than one party: the building owner, the fire sprinkler contractor and sometimes the fire department. Closing valves on a fire line can trigger alarms, so we coordinate with you first and follow the steps needed to keep the system covered.

Figuring out which type you have

The type is usually printed on the device or a tag attached to it. Without a label, look at the shape. RPs have a relief port underneath between two checks. Double checks have two check covers and no relief port. PVBs and SVBs have a bonnet on top.

There's no need to figure it out yourself. Send a photo when you book, or let the tester identify it when they arrive.

Older devices and test results

Device type matters less than condition when it comes to passing. A ten-year-old double check that has been rebuilt on schedule can pass easily, while a three-year-old RP on a line full of debris can fail.

That said, older devices do fail more often as rubber ages and parts wear. If yours is old enough that parts are getting hard to find, we'll mention it, so replacement can be planned instead of rushed.

Don't know which one you have?

A quick photo is usually enough for us to tell. Or read our comparison guide.

Questions

Do all types cost the same to test?

Pricing goes by size, not type: $105 for devices under 4 inches and $175 for 4 inches and up.

Which type is most common on homes?

On sprinkler lines it's usually a PVB or double check. On the main line it's often a double check or RP.

Can you test a device installed underground?

Yes. Let us know when you book if the vault fills with water or dirt so we come ready to clear it.

Is an RPZ the same as an RP?

Yes. Both names refer to a reduced pressure principle assembly.

Is the price different for an RP?

No. We charge by size: $105 under 4 inches, $175 for 4 inches and larger.

Do fire line devices need the fire department?

Usually not for the test itself, but we coordinate with you first since closing valves can trigger alarms.

How we handle backflow preventer testing in Ontario

Our approach is simple. Show up when we say we will, do the work right, and handle the paperwork so you don't have to. Every tester is certified, every gauge is kept in calibration, and filing with your water district is included.

Pricing is clear. Tests are a flat $105 for devices under 4 inches and $175 for 4 inches and larger, and anything beyond the test is quoted before we start. We're available seven days a week from 6am to 12pm, with emergency calls answered 24/7. Most Ontario appointments are within the same week, and you'll have a copy of your report by email when we're done.

Where we offer Backflow Preventer Testing

Our testers handle backflow Preventer Testing across Ontario and the surrounding area, from Upland, Montclair, Chino, Rancho Cucamonga and Pomona. Call for the next opening or schedule online.

Have a notice from your district?

Same-week appointments. We handle the paperwork.

Call NowSchedule